hello, today, all of a sudden our GE microwave, model, JVM3160RF4SS which we purchased in 2018 started tripping the circuit breaker. The circuit only trips when attempting to run a cook cycle. I am able to run the exhaust, all lights, open/close doors without any issues. While searching online for answers, i ran into several posts that mentioned checking the fuse. i have checked the fuse that is behind the plastic grill and it does not appear to be blown.

Asked by: Guest | Views: 392
Total answers/comments: 3
Guest [Entry]

Same problem with GE microwave mfg in 2018. When you try to start the microwave, breaker trips within a second.
Guest [Entry]

I just fixed one. The door monitor switch is the prime suspect, BUT not the only thing. If that switch is not activated when the door is closed it puts a direct short across the AC line, which is what trips the breaker, but it does not blow the internal fuse. The problem can also be caused by worn out plastic assy. that holds the switches allowing the activator to drop too low and not trip the switch - as it was in the one I fixed. You need to verify that the switch is functioning or not, then look closely at the area the activator rides over. If it looks rough and worn, it is a $35+ part. The switch is also being scammed for the same or more, but can be had on AliExpress for about $5.
Guest [Entry]

I have the same microwave, manufactured in 2018, tripping breaker, so I replace the door switch, it worked for a month, then I had to replace all 3 switches lasted another month. So done replacing microwave but not with a GE. Just tired of fixing it.