Why is my remote control box frying when installed?

Why is my remote control box frying when installed? This is a 54" Hunter Contempo Fan with Remote Model #59174, bought new in July of 2017. It was installed by someone else, and apparently worked fine for many months. However, when I moved in the fan and light did not operate via the remote (which as far as I know if the only way to turn it on). After disassembling things, I found the "Fan & Light Control" box and opened it up. This box is Part # K243111000.

Asked by: Guest | Views: 156
Total answers/comments: 2
mcgyver89 [Entry]

"Hi @luke ,

Here is a link to the User/Installation manual (found from this webpage).

The wiring (p.11) seems to indicate that the remote controls the amount of current to the fan motor and the lights. A resistor burning out indicates excess current, usually caused by a short circuit (s/c) or a s/c to Earth.

With the fan disconnected from everything, use an Ohmmeter to check the resistance between the white wire from the fan and:

the black wire from the fan. (this is the fan motor - I think)

the blue wire (or black/white stripe) from the fan. (this is the lights - I think)

The motor may read a low resistance as might the lights but not a s/c.

and also between the green/yellow stripe wire from the fan and:

the black wire from the fan

the blue wire (or black /white stripe)from the fan

This will test if there is a connection between either of the two circuits, (motor and light) and earth (which there shouldn't be).

If the fan motor is the problem, as it is less than 12 months old it may be that it is still covered by the Limited Lifetime Motor Warranty. You could try contacting Hunter fans at social@help.hunterfan.com. and ask if this is the case. It never hurts to ask.

As an aside, if you haven't already, it might be advisable to have one (or more) of these RCD (Residual Current Device - Safety Switch) installed in the power outlet and light circuits of the premises, as a safeguard against any future electrical problems. If it was a leakage to earth problem, the RCD would've tripped, isolating the circuit.

Update (05/03/2018)

Hi @luke ,

The readings for the motor seem rather high. I was expecting somewhere in the range of 30-200 Ohms for the motor winding. It may be that the run winding has burnt out and that you're reading leakage resistance through the capacitor / start winding. On starting most of the current goes through a lower resistance start winding, and if the start winding cut out switch was s/c for instance the start winding would still be ""in circuit' and therefore drawing excess current burning out the resistor. This is only speculation on my part.

To find out how it is wired you'd have to dig deeper into the fan. Personally I'd go the warranty route first , if still applicable.

I don't know how your particular fan motor is wired but I imagined that it would be something similar to the image below. Speed being controlled by the receiver box regulating the current supply to the fan

,

What is not shown in this image is that usually there is a centrifugal switch in the motor that o/c the start winding circuit (Aux winding in this particular image) when the motor gets up to speed.

With the light circuit, I may have misLED (pun intended) you. I overlooked that the fan has LED lights which may account for the high reading. You can't really test LEDs with an Ohmmeter accurately. You could try the diode test in the DMM if there is one (reverse the leads to see if it makes a difference) but again it depends how it is set up. The only good thing about what you tested is that there wasn't a very low resistance reading which could cause excess current to flow."
mcgyver89 [Entry]

I fried 2 hunter fan controllers by installing LED lights. Sucks