In ore concentration plant, single parameter and fixed value feeding control is a traditional method to control the feed rate of mobile crusher. This system is composed of recorder, SCR governor, belt scales, funnel automatic switching device, and three DC motor driving belt feeders. The control system can be realized by both modular instrumentation and computer.
How to Realize Automatic Control of the Feed Rate in mobile crusher?

In ore concentration plant, single parameter and fixed value feeding control is a traditional method to control the feed rate of mobile crusher. This system is composed of recorder, SCR governor, belt scales, funnel automatic switching device, and three DC motor driving belt feeders. The control system can be realized by both modular instrumentation and computer.

During controlling the feed rate, you should first set the volume of the ore in the regulator. When the deviation signal produced by ore changes deviating the given value outputs by the regulator, it can automatically changes the DC mA signal in the SCR governor and thus makes it output the voltage changes. The speed of the belt feeder is controlled by adjusting the DC motor armature voltage, which makes the feed rate close equal to the given value and then achieves the purpose of fixing the feed rate.

Electronic belt is used to test the feed rate of the mobile crusher, which can use the differential transformer to convert the displacement signal to voltage signal, or using photoelectric conversion to convert the belt scale counter to MA signal.

When the control system is working, if the funnel of the ore bin has no ore, belt scale outputs zero signals, the automatic switching devices makes the feeder of the no mine funnel close, and then open the feeder of mine funnel. Meanwhile, it can convert the output signal of the regulator to according SCR governor and then achieve the automatic switch of the feeder. When the ore bin has no ore or the funnel is clogged, belt weigher outputs no ore signal, the system automatically stops feeding and gives alarm signal. Then, the automatic control of the feed rate in mobile crusher is completed.
- https://www.affordablecebu.com/
 

Please support us in writing articles like this by sharing this post

Share this post to your Facebook, Twitter, Blog, or any social media site. In this way, we will be motivated to write articles you like.

--- NOTICE ---
If you want to use this article or any of the content of this website, please credit our website (www.affordablecebu.com) and mention the source link (URL) of the content, images, videos or other media of our website.

"How to Realize Automatic Control of the Feed Rate in mobile crusher?" was written by Mary under the Business category. It has been read 1377 times and generated 0 comments. The article was created on and updated on 25 December 2012.
Total comments : 0